Hach Intellical PHC745 Refillable Glass pH Electrodes

The Hach Intellical PHC745 is a digital combination pH electrode with a built-in temperature sensor. The PHC745 is a pH refillable electrode with a reverse sleeve reference junction embedding the RedRod technology.

Features

  • Red Rod technology provides fast, accurate and reproducible measurements
  • Probes can be moved between meters without the need to re-calibrate
  • Wide temperature range up to 100 °C
Your Price $854.00
Stock Drop Ships From Manufacturer  

Overview
The Hach Intellical PHC745 is a digital combination pH electrode with built-in temperature sensor. The PHC745 is a pH refillable electrode with a reverse sleeve reference junction embedding the RedRod technology to deliver exceptionally fast, stable, and accurate response times for accurate measurements within a wide temperature range. A 59-mL bottle of saturated KCl Electrode Filling Solution is included with the probe.

Applications
Thanks to its easy-to-clean and high-flow reverse sleeve reference junction, this high-performance laboratory glass pH electrode is ideal for measuring pH in samples prone to clogging traditional reference junctions such as wastewater influents, emulsions and viscous liquids. The PHC745 is not suitable for use with organic solvents or high-alkaline sample types.

Accuracy: ±0.01 pH
Application: Extremely Dirty Samples
Cable Length: 1 m (3.28 ft)
Electrode Type: RedRod / Refillable Reference Element / High Flow
Filling Solution: Saturated KCl (#25118026)
Junction: Reverse Sleeve Junction
Kit?: No
Length: 200 mm (7.87 in.)
Method Type: Laboratory: RedRod / Refillable Reference Element / High Flow
Parameter: pH
Probe Type: Standard
Product Kit: Model: PHC745
Accessories Included: None
Range: 0 - 14 pH
Reference Type: Red Rod
Resolution: 0.001/0.01/0.1
Sample depth: 18 mm (0.71 in.)
Sensor material: Glass
Sensor Type: pH Glass
Sodium (Alkalinity) error: <0.3 pH at pH 13 in 0.1 M NaOH
Special Features: Clogging Media
Temperature Accuracy: ±0.3 °C (±0.54 °F)
Temperature Range: –10 - 100 °C (14 - 212 °F)
Temperature Resolution: 0.1 °C (0.18 °F)
Test requirements: Parameter Needed: pH
Minimum Sample Depth (mm): 18
Thermistor: ATC
Warranty: 12 months
Weight: 0.1 kg
What's included?: IntelliCAL PHC745 Laboratory pH electrode with storage soaker bottle, 1 m cable, 59-mL bottle reference electrolyte filling solution (Saturated KCl solution), Test certificate, and Basic User Manual.
Questions & Answers
No Questions
Did you find what you were looking for?

Select Options

  Products 0 Item Selected
Image
Part #
Description
Price
Stock
Quantity
Hach Intellical PHC745 Refillable Glass pH Electrodes
PHC74501
Intellical PHC745 RedRod Refillable Glass pH Electrode (Clogging Media), 1m Cable
$854.00
Drop Ships From Manufacturer  
Notice: At least 1 product is not available to purchase online
×
Multiple Products

have been added to your cart

There are items in your cart.

Cart Subtotal: $xxx.xx

Go to Checkout

In The News

Angler-Driven Citizen Science: Monitoring Black Bass Populations in Arkansas

In Arkansas, the rugged terrain of the Ozark and Ouachita Mountains dominates the north and west, eventually yielding to the vast, fertile flatlands of the Mississippi River Delta to the east. Hundreds of reservoirs and lakes punctuate the landscape, while swift streams snake through the valleys and hills, eventually giving way to the slow-moving rivers and bayous in the south. The waterways of the state are teeming with life. Black bass dominate most of these ecosystems and have drawn anglers for centuries. The most sought-after fish in one of the country's most prominent fishing states, Arkansas treasures its black bass populations.

Read More

New Buoy Boosts White Lake’s Water Quality Monitoring and Conservation

White Lake in Western Michigan is a vestige of North America’s glacial past, and gets its name from an interpretation of the Indian, “Wabish-Sippe,” meaning the river with white clay. The twin towns of Whitehall and Montague, which nestle on White Lake’s shore, have shared a close connection with the lake since their foundation–from the growth of the lumbering industry, to industrializsation, the expansion of tourism, and most recently, environmental protection. The White Lake Association (WLA) was founded in 1988 by residents concerned about proposed development at the lake’s northern end.

Read More

Flow Photo Explorer: Studying Flows in the Penobscot River Basin

The flow dynamics of rivers and streams play an essential role in the chemical and physical functions of aquatic ecosystems. In Maine, varying flows in the Penobscot River Basin have impacted the health of the ecosystem, water resource use, and habitat suitability for native species—topics of particular concern to the Penobscot Indian Nation , who have been protecting and managing the waterway for millennia. Parts of the Penobscot basin have been monitored by the USGS stream gage network, which covers larger streams and rivers but excludes many of the small streams found on tribal lands.

Read More